Industry bodies publish joint guidance on waterproofing around flat-roof rooflights
NFRC, the Liquid Roofing and Waterproofing Association (LRWA), the Rooflight Association (RA) and the Single Ply Roofing Association (SPRA) have jointly developed guidance on waterproofing around rooflights and roof windows on flat roofs.
The guidance explains how membrane laps and reinforcement can create uneven surfaces beneath rooflight frames, affecting seals, fixings, and drainage. It covers upstand dimensions, corner detailing, proprietary kerbs, flashings and insulation continuity across a range of rooflight and waterproofing systems. Its central message is that rooflight and waterproofing details must be coordinated before installation, following both manufacturers’ requirements.
There is no universal detail suitable for every arrangement. Practical recommendations include resolving conflicting details before work starts, checking finished upstand dimensions and inspecting and photographing the completed waterproofing before the rooflight is installed. Required membrane layers should never be removed simply to create a flatter surface, and rooflights should not be forced onto uneven upstands by overtightening fixings.
By bringing together expertise from across the roofing and rooflight sectors, the guidance supports better coordination between designers, manufacturers, and installers, helping to reduce avoidable defects and improve the long-term performance of these important interfaces.