Management of Moisture in Buildings – Permavent Training Course

Permavent’s RIBA-approved CPD, Management of Moisture in Buildings – Pitched Roofing Designs is now available.

Modern pitched roofs are being asked to work harder than ever. Buildings are warmer, better insulated and increasingly airtight, while the way we live generates significant water vapour through cooking, showering, drying clothes and spending more time at home. In new buildings, this is compounded by moisture retained within materials such as plaster, mortar and concrete during construction.

Although mechanical extraction removes some moisture, it cannot prevent all water vapour from reaching the roof space. Moisture can travel through ceiling joints, loft hatches, service penetrations and gaps in the building envelope. If warm, moisture-laden air meets a cold surface below its dew point, condensation forms. Left unmanaged, this can reduce the effectiveness of insulation, damage roof timbers and internal finishes, encourage mould growth and compromise the long-term performance of the building.

Managing this risk requires more than choosing an underlay described as breathable. A pitched roof must be considered as a complete system, with the roof construction, insulation position, ceiling airtightness, ventilation provision, underlay and primary roof covering all working together. A change to one element can alter how moisture moves through the entire build-up.

BS 5250:2021 provides guidance for managing moisture in buildings, but it does not offer one ventilation solution for every roof. High-resistance, low-resistance vapour-permeable, and air and vapour permeable underlays all perform differently and have different ventilation requirements. Product certification and manufacturer guidance must therefore be considered alongside the conditions of the individual project.

The roof covering itself also influences the strategy. Many clay and concrete tiles and natural slates are sufficiently air open to allow moisture to dissipate beyond the underlay. Fibre-cement slates and metal roof coverings may be less air open, potentially changing the requirement for counter-battens and ventilation through the batten space. Overlooking this relationship can allow moisture to accumulate, even where the roof void appears to have been correctly designed.

The growth of integrated solar adds a further consideration. Because in-roof panels replace part of the primary roof covering, they change the airflow and moisture behaviour of the roof. Unless evidence demonstrates otherwise, integrated solar should be treated as air impermeable and the ventilation design adjusted accordingly. On-roof solar sits above the primary covering, meaning the usual roof ventilation guidance continues to apply.

Permavent’s RIBA-approved CPD, Management of Moisture in Buildings – Pitched Roofing Designs, brings these interconnected issues together. Developed for architects, specifiers, housebuilders and other construction professionals, it uses current standards, project experience and practical examples to explain why apparently compliant roofs can still experience condensation. Delivered free of charge by Permavent’s technical team, the session helps attendees identify risk earli

Apex_Permavent_MoM-300x174.png

er, make more informed specification decisions and design pitched roofs that manage moisture effectively throughout the life of the building.